Home > Stages > Heating Stages > Linkam Heating Stages > Linkam Examina Pressure System


Linkam Examina Pressure System
Linkam Examina Pressure System
Linkam Examina Pressure System

Designed for higher presusure experiments up to 14 bar in the temperature range ambient to +500°C (to extend the Temperature range down to -120°C order 14050 LNP95 Liquid Nitrogen Automated Cooling System)

Features and Benefits:

By pressurizing the sample chamber up to 14bar the Examina pressure stage can be used to investigate the effects of pressure on the sample during heating and cooling experiments. This stage has been used in applications where minimizing sample evaporation and sublimation are required.

Similar in performance to the standard Examina range of heating and freezing stages, the Examina Pressure Stage utilizes a stainless steel reinforced base plate, reinforced lid and base inserts and 1mm thick glass windows to enable pressurizing the sample chamber up to 14bar. A safety release valve ensures the system cannot be over pressurized.

The T95-LinkPad controller enables the user to quickly program multiple ramp temperature profiles by simply tapping the intuitive controls on the LinkPad LCD touch screen

A manually operated digital display pressure pump can be purchased as an option with the stage.

To cool samples from ambient down to -196°C, add the LNP95 liquid nitrogen cooling system. This highly efficient LN2 pump, using proprietary pumps and tubing, automatically controls pumping rate to ensure minimal LN2 is required


Specifications at 14bar:

Click Here for a PDF About Linkam's Examina Pressure System
  • Temperature Range -120°C to 500 °C
  • Sample area of 22mm diameter
  • 32 ramp temperature profile programming
  • No PC required
  • Pressure tested to 14bar
  • Can be used with transmitted or reflected light
  • Mounts directly to microscope table or substage
  • Stage body size - 160 x 80 x 24 mm
  • 100 ohm platinum sensor 1/10th din standard class A
  • Temperature stability < 0.1°C
  • Direct injection of coolant into block
  • Highly conductive metal for improved heat transfer
  • Maximum heating of 150°C/min
  • Response time of <1 second at 5°C/min at 50°C
  • Objective lens minimum working distance 6.6mm
  • Condenser lens minimum working distance 14.5mm


Examina Pressure System Includes:

THMS600PS stage

T95-LinkPad System Controller

All necessary cables

OPTIONAL EXTRAS

*Cooling option required to extend range to -196°C

*LNP95 liquid nitrogen cooling system

 


<<< Go Back



Spectra carries a wide variety of stages. Select from one of the manufacturers below to find what you need.
 
2020 Technology Stages linkam Systems and StagesInstec hot and Cold Stages
 

THMS600PS stage with stage clamps being attached to circular dovetail substage.

THMS600PS stage with stage clamps being attached to circular dovetail substage.

 

 


Request a quote!
Spectra Services Downloads